public static final class
ProfileOptions.Builder
Next ID: 11
tensorflow.ProfileOptions
Public Methods
ProfileOptions.Builder |
addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
|
ProfileOptions |
build()
|
ProfileOptions | |
ProfileOptions.Builder |
clear()
|
ProfileOptions.Builder |
clearDeviceTracerLevel()
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. |
ProfileOptions.Builder |
clearDeviceType()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. |
ProfileOptions.Builder |
clearDurationMs()
The local profiler collects `duration_ms` milliseconds of data. |
ProfileOptions.Builder |
clearEnableHloProto()
Whether serialize hlo_proto when XLA is used. |
ProfileOptions.Builder |
clearField(com.google.protobuf.Descriptors.FieldDescriptor field)
|
ProfileOptions.Builder |
clearHostTracerLevel()
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. |
ProfileOptions.Builder |
clearIncludeDatasetOps()
We don't collect the dataset ops by default for better trace-viewer scalability. |
ProfileOptions.Builder |
clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof)
|
ProfileOptions.Builder |
clearPythonTracerLevel()
Whether enable python function calls tracing. |
ProfileOptions.Builder |
clearRepositoryPath()
Directory to save profile data to. |
ProfileOptions.Builder |
clearStartTimestampNs()
The local profiler starts profiling at this Unix timestamp in nanoseconds. |
ProfileOptions.Builder |
clearVersion()
Some default value of option are not proto3 default value. |
ProfileOptions.Builder |
clone()
|
ProfileOptions | |
final static com.google.protobuf.Descriptors.Descriptor | |
com.google.protobuf.Descriptors.Descriptor | |
int |
getDeviceTracerLevel()
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. |
ProfileOptions.DeviceType |
getDeviceType()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. |
int |
getDeviceTypeValue()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. |
long |
getDurationMs()
The local profiler collects `duration_ms` milliseconds of data. |
boolean |
getEnableHloProto()
Whether serialize hlo_proto when XLA is used. |
int |
getHostTracerLevel()
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. |
boolean |
getIncludeDatasetOps()
We don't collect the dataset ops by default for better trace-viewer scalability. |
int |
getPythonTracerLevel()
Whether enable python function calls tracing. |
String |
getRepositoryPath()
Directory to save profile data to. |
com.google.protobuf.ByteString |
getRepositoryPathBytes()
Directory to save profile data to. |
long |
getStartTimestampNs()
The local profiler starts profiling at this Unix timestamp in nanoseconds. |
int |
getVersion()
Some default value of option are not proto3 default value. |
final boolean | |
ProfileOptions.Builder |
mergeFrom(com.google.protobuf.Message other)
|
ProfileOptions.Builder |
mergeFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry)
|
final ProfileOptions.Builder |
mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
|
ProfileOptions.Builder |
setDeviceTracerLevel(int value)
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. |
ProfileOptions.Builder |
setDeviceType(ProfileOptions.DeviceType value)
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. |
ProfileOptions.Builder |
setDeviceTypeValue(int value)
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. |
ProfileOptions.Builder |
setDurationMs(long value)
The local profiler collects `duration_ms` milliseconds of data. |
ProfileOptions.Builder |
setEnableHloProto(boolean value)
Whether serialize hlo_proto when XLA is used. |
ProfileOptions.Builder |
setField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
|
ProfileOptions.Builder |
setHostTracerLevel(int value)
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. |
ProfileOptions.Builder |
setIncludeDatasetOps(boolean value)
We don't collect the dataset ops by default for better trace-viewer scalability. |
ProfileOptions.Builder |
setPythonTracerLevel(int value)
Whether enable python function calls tracing. |
ProfileOptions.Builder |
setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value)
|
ProfileOptions.Builder |
setRepositoryPath(String value)
Directory to save profile data to. |
ProfileOptions.Builder |
setRepositoryPathBytes(com.google.protobuf.ByteString value)
Directory to save profile data to. |
ProfileOptions.Builder |
setStartTimestampNs(long value)
The local profiler starts profiling at this Unix timestamp in nanoseconds. |
final ProfileOptions.Builder |
setUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
|
ProfileOptions.Builder |
setVersion(int value)
Some default value of option are not proto3 default value. |
Inherited Methods
Public Methods
public ProfileOptions.Builder addRepeatedField (com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
public ProfileOptions.Builder clearDeviceTracerLevel ()
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. - Level 1 is used to enable device traces. - More levels might be defined for specific device for controlling the verbosity of the trace.
uint32 device_tracer_level = 3;
public ProfileOptions.Builder clearDeviceType ()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. DeviceType::CPU: only CPU will be profiled. DeviceType::GPU: only CPU/GPU will be profiled. DeviceType::TPU: only CPU/TPU will be profiled.
.tensorflow.ProfileOptions.DeviceType device_type = 6;
public ProfileOptions.Builder clearDurationMs ()
The local profiler collects `duration_ms` milliseconds of data. If the value is 0, profiling continues until interrupted.
uint64 duration_ms = 9;
public ProfileOptions.Builder clearEnableHloProto ()
Whether serialize hlo_proto when XLA is used. (version >= 1)
bool enable_hlo_proto = 7;
public ProfileOptions.Builder clearHostTracerLevel ()
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. - Level 1 enables tracing of only user instrumented (or default) TraceMe. - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high level program execution details (expensive TF ops, XLA ops, etc). This is the default. - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose (low-level) program execution details (cheap TF ops, etc).
uint32 host_tracer_level = 2;
public ProfileOptions.Builder clearIncludeDatasetOps ()
We don't collect the dataset ops by default for better trace-viewer scalability. The caller can mannually set this field to include the ops.
bool include_dataset_ops = 1;
public ProfileOptions.Builder clearPythonTracerLevel ()
Whether enable python function calls tracing. Runtime overhead ensues if enabled. Default off. (version >= 1)
uint32 python_tracer_level = 4;
public ProfileOptions.Builder clearRepositoryPath ()
Directory to save profile data to. No-op when empty.
string repository_path = 10;
public ProfileOptions.Builder clearStartTimestampNs ()
The local profiler starts profiling at this Unix timestamp in nanoseconds.
uint64 start_timestamp_ns = 8;
public ProfileOptions.Builder clearVersion ()
Some default value of option are not proto3 default value. Use this version to determine if we should use default option value instead of proto3 default value.
uint32 version = 5;
public static final com.google.protobuf.Descriptors.Descriptor getDescriptor ()
public com.google.protobuf.Descriptors.Descriptor getDescriptorForType ()
public int getDeviceTracerLevel ()
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. - Level 1 is used to enable device traces. - More levels might be defined for specific device for controlling the verbosity of the trace.
uint32 device_tracer_level = 3;
public ProfileOptions.DeviceType getDeviceType ()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. DeviceType::CPU: only CPU will be profiled. DeviceType::GPU: only CPU/GPU will be profiled. DeviceType::TPU: only CPU/TPU will be profiled.
.tensorflow.ProfileOptions.DeviceType device_type = 6;
public int getDeviceTypeValue ()
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. DeviceType::CPU: only CPU will be profiled. DeviceType::GPU: only CPU/GPU will be profiled. DeviceType::TPU: only CPU/TPU will be profiled.
.tensorflow.ProfileOptions.DeviceType device_type = 6;
public long getDurationMs ()
The local profiler collects `duration_ms` milliseconds of data. If the value is 0, profiling continues until interrupted.
uint64 duration_ms = 9;
public boolean getEnableHloProto ()
Whether serialize hlo_proto when XLA is used. (version >= 1)
bool enable_hlo_proto = 7;
public int getHostTracerLevel ()
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. - Level 1 enables tracing of only user instrumented (or default) TraceMe. - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high level program execution details (expensive TF ops, XLA ops, etc). This is the default. - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose (low-level) program execution details (cheap TF ops, etc).
uint32 host_tracer_level = 2;
public boolean getIncludeDatasetOps ()
We don't collect the dataset ops by default for better trace-viewer scalability. The caller can mannually set this field to include the ops.
bool include_dataset_ops = 1;
public int getPythonTracerLevel ()
Whether enable python function calls tracing. Runtime overhead ensues if enabled. Default off. (version >= 1)
uint32 python_tracer_level = 4;
public String getRepositoryPath ()
Directory to save profile data to. No-op when empty.
string repository_path = 10;
public com.google.protobuf.ByteString getRepositoryPathBytes ()
Directory to save profile data to. No-op when empty.
string repository_path = 10;
public long getStartTimestampNs ()
The local profiler starts profiling at this Unix timestamp in nanoseconds.
uint64 start_timestamp_ns = 8;
public int getVersion ()
Some default value of option are not proto3 default value. Use this version to determine if we should use default option value instead of proto3 default value.
uint32 version = 5;
public final boolean isInitialized ()
public ProfileOptions.Builder mergeFrom (com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry)
Throws
IOException |
---|
public final ProfileOptions.Builder mergeUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)
public ProfileOptions.Builder setDeviceTracerLevel (int value)
Levels of device tracing: (version >= 1) - Level 0 is used to disable device traces. - Level 1 is used to enable device traces. - More levels might be defined for specific device for controlling the verbosity of the trace.
uint32 device_tracer_level = 3;
public ProfileOptions.Builder setDeviceType (ProfileOptions.DeviceType value)
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. DeviceType::CPU: only CPU will be profiled. DeviceType::GPU: only CPU/GPU will be profiled. DeviceType::TPU: only CPU/TPU will be profiled.
.tensorflow.ProfileOptions.DeviceType device_type = 6;
public ProfileOptions.Builder setDeviceTypeValue (int value)
Device type to profile/trace: (version >= 1) DeviceType::UNSPECIFIED: All registered device profiler will be enabled. DeviceType::CPU: only CPU will be profiled. DeviceType::GPU: only CPU/GPU will be profiled. DeviceType::TPU: only CPU/TPU will be profiled.
.tensorflow.ProfileOptions.DeviceType device_type = 6;
public ProfileOptions.Builder setDurationMs (long value)
The local profiler collects `duration_ms` milliseconds of data. If the value is 0, profiling continues until interrupted.
uint64 duration_ms = 9;
public ProfileOptions.Builder setEnableHloProto (boolean value)
Whether serialize hlo_proto when XLA is used. (version >= 1)
bool enable_hlo_proto = 7;
public ProfileOptions.Builder setField (com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
public ProfileOptions.Builder setHostTracerLevel (int value)
Levels of host tracing: (version >= 1) - Level 0 is used to disable host traces. - Level 1 enables tracing of only user instrumented (or default) TraceMe. - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high level program execution details (expensive TF ops, XLA ops, etc). This is the default. - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose (low-level) program execution details (cheap TF ops, etc).
uint32 host_tracer_level = 2;
public ProfileOptions.Builder setIncludeDatasetOps (boolean value)
We don't collect the dataset ops by default for better trace-viewer scalability. The caller can mannually set this field to include the ops.
bool include_dataset_ops = 1;
public ProfileOptions.Builder setPythonTracerLevel (int value)
Whether enable python function calls tracing. Runtime overhead ensues if enabled. Default off. (version >= 1)
uint32 python_tracer_level = 4;
public ProfileOptions.Builder setRepeatedField (com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value)
public ProfileOptions.Builder setRepositoryPath (String value)
Directory to save profile data to. No-op when empty.
string repository_path = 10;
public ProfileOptions.Builder setRepositoryPathBytes (com.google.protobuf.ByteString value)
Directory to save profile data to. No-op when empty.
string repository_path = 10;
public ProfileOptions.Builder setStartTimestampNs (long value)
The local profiler starts profiling at this Unix timestamp in nanoseconds.
uint64 start_timestamp_ns = 8;
public final ProfileOptions.Builder setUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)
public ProfileOptions.Builder setVersion (int value)
Some default value of option are not proto3 default value. Use this version to determine if we should use default option value instead of proto3 default value.
uint32 version = 5;